2,463 research outputs found

    Some Aspects of New CDM Models and CDM Detection Methods

    Full text link
    We briefly review some recent Cold Dark Matter (CDM) models. Our main focus are charge symmetric models of WIMPs which are not the standard SUSY LSP's (Lightest Supersymmetric Partners). We indicate which experiments are most sensitive to certain aspects of the models. In particular we discuss the manifestations of the new models in neutrino telescopes and other set-ups. We also discuss some direct detection experiments and comment on measuring the direction of recoil ions--which is correlated with the direction of the incoming WIMP. This could yield daily variations providing along with the annual modulation signatures for CDM.Comment: 14 page

    Modelling and optimisation of the operation of a radiant warmer

    Get PDF
    This paper presents numerical calculations of the temperature field obtained for the case of a neonate placed under a radiant warmer. The results of the simulations show a very non-uniform temperature distribution on the skin of the neonate, which may cause increased evaporation leading to severe dehydration. For this reason, we propose some modifications on the geometry and operation of the radiant warmer, in order to make the temperature distribution more uniform and prevent the high temperature gradients observed on the surface of the neonate. It is concluded that placing a high conductivity blanket over the neonate and introducing additional screens along the side of the mattress, thus recovering the radiation heat escaping through the side boundaries, helped providing more uniform temperature fields.The European Union for the Marie Curie Fellowship grant awarded to the Centre for CFD, University of Leeds

    Discovery and Measurement of Sleptons, Binos, and Winos with a Z'

    Get PDF
    Extensions of the MSSM could significantly alter its phenomenology at the LHC. We study the case in which the MSSM is extended by an additional U(1) gauge symmetry, which is spontaneously broken at a few TeV. The production cross-section of sleptons is enhanced over that of the MSSM by the process pp→Z′→ℓ~ℓ~∗pp\to Z' \to \tilde{\ell} \tilde{\ell}^*, so the discovery potential for sleptons is greatly increased. The flavor and charge information in the resulting decay, ℓ~→ℓ+LSP\tilde{\ell} \to \ell + {LSP}, provides a useful handle on the identity of the LSP. With the help of the additional kinematical constraint of an on-shell Z', we implement a novel method to measure all of the superpartner masses involved in this channel. For certain final states with two invisible particles, one can construct kinematic observables bounded above by parent particle masses. We demonstrate how output from one such observable, m_T2, can become input to a second, increasing the number of measurements one can make with a single decay chain. The method presented here represents a new class of observables which could have a much wider range of applicability.Comment: 20 pages, 15 figures; v2 references added and minor change

    Zentrale Zugseilsysteme – vollautomatische, kontinuierliche Kallusdistraktion zur Behandlung langstreckiger Knochendefekte

    Get PDF
    Distraction osteogenesis involving bone transport enables the reconstruction of large bone defects. The main bone fragments are usually stablilised externally, an intermediate bone segment is separated and moved through the defect at a rate of about 1 mm/day. New high-quality bone is built up in the constantly enlarging osteotomy gap. A major problem associated with the method is the fact that the fixation pins are also moved over the same distance, and cut through the soft tissue, often resulting in painful pin tract infections and ugly scars. An automatic motorized bone transport system employing a single central cable now eliminates this problem. The system can be combined with any external fixateur, since the relevant implanted parts for bone transport are independent of the external stabilizer. The surgical procedure, which is easy on the patient, consists of bone segment separation, central cable fixation, and stabilisation of the main fragments, and requires the use of numerous special tools. The distraction itself results in significantly less soft tissue irritation and pain. Pin tract infections are rare, so that changeover to internal fixation after completion of bone transport carries little risk of infection. This article details the technical features of the stabilizing system and the transport and the control systems, and describes the clinical application in a patient

    Systematic Improvement of Parton Showers with Effective Theory

    Full text link
    We carry out a systematic classification and computation of next-to-leading order kinematic power corrections to the fully differential cross section in the parton shower. To do this we devise a map between ingredients in a parton shower and operators in a traditional effective field theory framework using a chain of soft-collinear effective theories. Our approach overcomes several difficulties including avoiding double counting and distinguishing approximations that are coordinate choices from true power corrections. Branching corrections can be classified as hard-scattering, that occur near the top of the shower, and jet-structure, that can occur at any point inside it. Hard-scattering corrections include matrix elements with additional hard partons, as well as power suppressed contributions to the branching for the leading jet. Jet-structure corrections require simultaneous consideration of potential 1 -> 2 and 1 -> 3 branchings. The interference structure induced by collinear terms with subleading powers remains localized in the shower.Comment: 54 pages, 24 figures, plus a few appendices. v2: included a parameter "eta" to account for energy loss, title improved, journal versio

    Zugkraftmessungen beim knöchernen Segmenttransport – in vivo Untersuchungen am Menschen

    Get PDF
    Bone transport applying the principle of distraction osteogenesis makes it possible to reconstruct long bone defects caused by trauma or resection of bone tumors. The method employing a central cable, developed in Munich, is especially suitable for such applications. The main bone fragments are stabilized by an external fixateur, and bone transport is effected with a single central cable fixed to the tip of the segment, and driven by an external, programmable motor. In 15 patients the tractive forces during the entire bone transport were measured with a strain gauge incorporated within the cable. On the basis of the force profiles characteristics normal bone transport (forces between 150 - 250 N) can be distinguished from a critical transport (forces > 250 N) with the risk of premature consolidation. There is some evidence that at a very high level of force, just before premature consolidation a very effective form of bone transport with good bone neoformation can be achieved. Transport systems employing a central cable allow this special form of distraction osteogenesis, since there is continuous force monitoring, and there is the option of employing the traction force as a control factor in a loop

    Nanomechanical and Morphological Characterization of Tungsten Trioxide (WO3) Thin Films Grown by Atomic Layer Deposition

    Get PDF
    This study investigates the nanomechanical properties and surface morphology of tungsten oxide WO3thin films deposited on p-type Si(100) substrates using atomic layer deposition (ALD) technology with 2000 ALD deposition cycles at a growth temperature of 300°C and annealed at different temperatures. The samples were further furnace annealed at 500, 600 and 700°C for 60 min. The influence of the deposition process on the structure and properties of the WO3 films is discussed, presented and correlated to the characteristic features of the ALD technique. The results depict significant difference in the hardness and modulus measurements between the as deposited sample and the annealed ones. The hardness and modulus drop from 14 and 170 GPa for the as deposited sample to 10 and 140 GPa for the annealed ones respectively. Surface roughness was observed to increase with annealing temperature and the initially amorphous as deposited sample reached complete recrystallization and transformed into polycrystalline films as indicated by XRD

    Electrical and Structural Properties of \u3ci\u3ep-n\u3c/i\u3e Junctions in cw Laser Annealed Silicon

    Get PDF
    Depth profiles of the electrical quality of ion implanted and cw laser annealed p-n junctions in silicon are obtained for the first time by secondary ion mass spectroscopy. A comparison with the crystallographic properties of the surface and the junction as observed by Nomarski optical microscopy as well as cross-sectional and plan view transmission electron microscopy is made. Samples containing slip dislocations show better insulation and a lower reverse bias current across the p-n junction as compared to samples with a perfect surface in agreement with current-voltage characteristics. Small dislocation loops located at the junction are found to degrade the junction quality

    Electrostatic Design and Conditioning of a Triple Point Junction Shield for a −200 kV DC High Voltage Photogun

    Get PDF
    Nuclear physics experiments performed at the Continuous Electron Beam Accelerator Facility (CEBAF) at the Jefferson Lab require a DC high voltage photogun to generate polarized electron beams from GaAs photocathodes. The photogun uses a tapered ceramic insulator that extends into the vacuum chamber and mechanically holds the cathode electrode. Increasing the operating voltage from nominal −130 kV to −200 kV will provide lower beam emittance, better transmission through injector apertures, and improved photocathode lifetime. This desire to increase the photogun operating voltage led to the design of a triple-point-junction shield electrode which minimizes the electric field at the delicate insulator-metal-vacuum interface and linearizes the potential across the insulator, thus reducing the risk of arcing along the ceramic insulator. This work describes the results obtained using COMSOL® electrostatic-field simulation software and presents the high voltage conditioning results of the upgraded −200 kV CEBAF photogun. Published by AIP Publishing
    • …
    corecore